On the other hand, the in vivo assays of whole cells should not be degassed for “resetting” reasons, since this will disturb the equilibrium of the cells even more. Hydrogen yield measurements by the water displacement method in a gas trap To determine the total amount and volume of H2 gas produced by an S-depleted algal culture, H2 gas collection can be achieved with a simple laboratory-assembled gas trap apparatus, based on the water displacement method. Flat culture bottles (usually Roux Nec-1s supplier type) are fitted with an air-tight silicone or rubber stopper, perforated with a gas port (either a narrow piece of glass tubing or a Gauge 10 needle). Teflon tubing (HPLC,
Aminco, Lake Forest, CA), attached to the outside-protruding portion of the gas port, is used to conduct the gas evolved by the algae in the culture bottles to an inverted burette or graduated cylinder filled with H2O (Fig. 5). The volume of the gas collected in the burette can be measured directly from the volume of water displacement. A standard GC
apparatus can be used to determine the levels of N2, O2, MGCD0103 solubility dmso CO2 and H2 in the headspace of the reactor. Fig. 5 H2-production measurements of S depleted green algae in the laboratory using gas traps. The gases produced by the algae are collected in inverted graduated P005091 in vitro cylinders via the water displacement method. Samples of the gas can be removed utilizing syringes with long and bended needles. As the cells pass into the H2-producing phase, yields of H2 can be measured directly from the volume of the Amylase water displaced in the graduated cylinders This simple setup can be easily assembled. However, there are key methodology issues to be kept in mind. H2 is the smallest of all the molecules and a volatile gas at room temperature. It can easily escape through material that is normally impermeable to air and water, or leak through connections that are not hydrogen-tight. Accordingly, connections of tubes to bottles and stopper perforations have to be
leak-proof and ultra-tight. If necessary, such connections and perforations can be additionally sealed with silicone grease or oil. Chlorophyll fluorescence-based characterization of the photosynthetic apparatus during hydrogen production In vivo chlorophyll a fluorescence is a powerful non-invasive technique which allows to probe and assess the functional status of the photosynthetic apparatus. As such, in vivo Chl a fluorescence has found many applications in photosynthesis research (Papgeorgiou et al. 2007). This simple measurement technique, which is described in a separate chapter in this issue (a good overview is also given by Baker 2008), offers insight into the induction of H2-production upon S-deprivation. As mentioned above, the significant H2-production capability of C. reinhardtii depends on photosynthesis.